Controlled removal of human stratum corneum by pulsed laser

1987 
Abstract A new method is presented for controlled removal of the stratum corneum of human skin. An excimer laser (193 nm wavelength, 14 ns pulsewidth) was used to remove stratum corneum from in vitro human skin samples by an ablative process. The tritiated water ( 3 H 2 O) permeability constant and electrical resistance of skin samples were measured in a diffusion chamber apparatus to quantify the enhancement of skin permeability. Each laser pulse ablates about a micrometer of stratum corneum, which allows controlled removal of tissue. The maximum specific enhancement of the 3 H 2 O permeability constant obtained after complete stratum corneum removal depends on the laser pulse energy used. The most gentle laser ablation, achieved with a radiant exposure of 70 mJ/cm 2 per pulse, produced a 124-fold enhancement, which is comparable to that achieved after stratum corneum removal by tape-stripping or removal of epidermis by mild heat treatment. Rapid tissue ablation occurred at higher radiant exposures of 170–480 mJ/cm 2 per pulse, but only a 45-fold enhancement of permeability was achieved. The precision with which stratum corneum can be ablated using excimer laser pulses may allow further basic research on the internal structure of stratum corneum and on the reepithelization in controlled wounds. The technique may prove useful clinically to enhance percutaneous transport in applications such as topical delivery of drugs, patch testing, and percutaneous blood gas monitoring.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    14
    References
    108
    Citations
    NaN
    KQI
    []