language-icon Old Web
English
Sign In

The Bevalac long spill

1993 
The Bevalac extraction time was increased from 1 to a maximum of 9.5 seconds, thus increasing the synchrotron duty factor and the data rate for experiments by a factor of 2-3, depending on the magnetic field. This slow rate of extraction required improved control of beam time structure, since magnet ripple remained approximately constant while the spill rate was decreased. Measurements of spill structure for the long spill are presented. Changes made to the accelerator systems are described, as well as tuning procedures found to be necessary, and the ultimate hardware limits found for the spill length. >
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    0
    Citations
    NaN
    KQI
    []