Testing of Active Rectification Topologies on a Six-Phase Rotating Brushless Outer Pole PM Exciter

2018 
The static exciter is dominating among large grid-connected generators due to the weak dynamic performance of conventional brushless exciters. In this contribution, a six-phase double-star outer pole permanent magnet rotating brushless exciter is evaluated with different active rectification topologies. Both thyristor-based and chopper-based topologies are considered. A high speed response brushless excitation system is obtained by replacing the conventional rotating diode bridge rectifier with the proposed active rectification topologies on the shaft. The given two-stage system generates its own excitation power directly from the shaft, contrary to static exciters. The selection of an appropriate rectification topology could minimize the rotor armature phase currents for a given generator field current. The objective is a high-power factor and a high utilization of the exciter machine. An optimal rectification topology makes higher ceiling currents was possible, improving the transient behavior of the synchronous generator. In this paper, we show that six-phase topologies add complexity, but improve exciter redundancy, increase the available ceiling voltage, and reduce the steady-state torque ripple. Experimental results are given for validating the models implemented for the analysis.