Tuning the narrow-band beam position monitor sampling clock to remove the aliasing errors in APS storage ring orbit measurements
2007
The Advanced Photon Source storage ring employs a real-time orbit correction system to reduce orbit motion up to 50 Hz. This system uses up to 142 narrow-band rf beam position monitors (Nbbpms) in a correction algorithm by sampling at a frequency of 1.53 kHz. Several Nbbpms exhibit aliasing errors in orbit measurements, rendering these Nbbpms unusable in real-time orbit feedback. The aliasing errors are caused by beating effects of the internal sampling clocks with various other processing clocks residing within the BPM electronics. A programmable external clock has been employed to move the aliasing errors out of the active frequency band of the real-time feedback system (RTFB) and rms beam motion calculation. This paper discusses the process of tuning and provides test results.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
1
References
1
Citations
NaN
KQI