In this letter we report on the direct density measurement in a shock compressed aluminum target using hard x-ray radiography. Experimental data employing a molybdenum Kα source at 17.5keV, generated with a short pulse laser are presented. High spatial resolution was obtained thanks to a new design for the backlighter geometry. Density values deduced from radiography are compared to predictions from hydrodynamic simulations, which have been calibrated in order to reproduce shock velocities measured from a rear-side self-emission diagnostic. Our results reveal the great potential of this technique as a diagnostic tool for direct density measurements in dense high-Z opaque materials.