Health hazard evaluation report HETA 91-0292-2467, Magnetics Division of Spang and Company, Butler, Pennsylvania

1994 
In response to an employee request, an investigation was begun into possible exposures to paint, paint thinners, and Freon at the Magnetics Division of Spang and Company (SIC-3679), Butler, Pennsylvania. The division employed about 450 people and manufactured two types of magnetic cores used in a variety of electronic devices. Workers in the Tape Core Paint Room had experienced light headedness or fainted episodes. Only one sample contained measurable levels of 2-ethoxyethyl-acetate (111159) but the level was 0.25 parts per million (ppm), one half of the NIOSH recommended exposure limit for full shift time weighted average exposure. Methylene-chloride (75092) was detected in all but one of the air samples with levels ranging up to 35ppm. One personal breathing zone sample had a lead (7439921) concentration of 36 micrograms/cubic meter (microg/m3) which exceeded the OSHA action level for lead of 30 microg/m3. The paint booth exhaust systems appeared to be operating efficiently and there were good work practices among the painters. The authors conclude that workers were exposed to methylene-chloride, considered by NIOSH to be a potential occupational carcinogen. Exposures to lead and 2-ethoxyethyl-acetate may exceed the evaluation criteria. Some workers may experience symptoms when working near solvents and paints, evenmore » though the measured exposures were below the permissible exposure limits. The authors recommend that efforts be made to reduce exposures in the paint room.« less