Electric Explosion of Aluminum Metallized Film
2009
Two types of capacitor-grade aluminum metallized polypropylene film were studied to investigate the factors that affect specific action integral and energy dissipation in the electrical explosion of a film, a phenomenon that occurs when a film is exposed to a high-density current pulse on the order of 10 7 - 10 8 A/cm 2 . The factors studied include film cross-sectional area, film length, film sheet resistance, and discharge circuit inductance. All film samples were subjected to a 2.5-kV capacitive discharge. The basic principles of the exploding-film phenomenon and the detailed effects of the stated factors are discussed.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
17
References
9
Citations
NaN
KQI