Pressure ulcer prevention in intensive care - a randomised control trial of two pressure-relieving devices.
2005
Summary
Pressure sores are a potential complication of intensive care. Modern methods of pressure sore prevention centre around the use of pressure-relieving devices. Few studies exist that confirm the effectiveness of these devices. This study evaluates the effectiveness of two devices, the Hill-Rom Duo® mattress and the KCI TheraPulse®. High-risk patients were randomly assigned to receive one of two devices. We excluded those patients who had pressure sores upon admission. Those patients that did develop a pressure sore had their wound digitally photographed and graded by two independent tissue viability nurses. Sixty-two patients were included (30 TheraPulse® , 32 Duo®). Nine developed a pressure sore (6 Duo®, 3 TheraPulse®). No statistical differences between the two devices could be found. The longer a patient was nursed on a device, the greater the risk of pressure sore development. Despite the use of these devices, pressure sores can still develop in the Intensive Care patient population.