Background:The aim of this biomechanical cadaver study of calcaneal fractures was to investigate whether a locking calcaneal plate provides more stiffness in osteoporotic bone compared to a non-locking plate.Materials and Methods:Sixteen fresh frozen bone mineral density (BMD)-matched cadaver feet were tested in a four-part model of a Sanders Type IIB calcaneal fracture. The fractures were fixed either with a non-locking AO (Sanders) plate or an interlocking AO plate (Synthes, Paoli, PA) to the lateral calcaneal wall with six screws. Specimens were subjected to cyclic loading which was increased stepwise to full body weight. Displacement of the posterior facet fragment was measured with an optical tracking system in the sagittal and transverse planes.Results:No statistically significant differences were observed between the non-locking and the locking plates with respect to number of cycles to failure or 1-mm displacement of the posterior facet. The initial stiffness was significantly higher for non-locki...