Improved Diastolic Function Is Associated With Higher Cardiac Output in Patients With Heart Failure Irrespective of Left Ventricular Ejection Fraction

2017 
BackgroundLittle is known regarding the impact of diastolic function on cardiac output (CO) in patients with heart failure, particularly in patients with lower ejection fraction. This study aimed to evaluate the impact of end‐diastolic pressure–volume relationship (EDPVR) on CO and end‐diastolic pressure (EDP). Methods and ResultsWe retrospectively analyzed 1840 consecutive patients who underwent heart catheterization. We divided patients into 8 groups according to ejection fraction (EF) (35–45%, 46–55%, 56–65%, and 66–75%) and EDP (>16 or ≤16 mm Hg). We estimated EDPVR from single measurements in the catheterization data set. Then, we replaced EDPVRs of high‐EDP groups with those of normal‐EDP groups and compared CO before and after EDPVR replacement. Normalized EDPVR significantly increased CO at EDP=10 mm Hg regardless of EF (EF 35–45%, from 4.5±1.6 to 4.9±1.0; EF 46–55%, 4.6±1.3 to 5.1±1.1; EF 56–65%, 4.9±1.5 to 5.2±1.0; EF 66–75%, 4.9±1.5 to 5.2±1.1). Changes in CO were similar across EF groups. Conc...