Usefulness of intraoperative diagnosis of hepatic tumors located at the liver surface and hepatic segmental visualization using indocyanine green- photodynamic eye imaging
2015
Abstract Background To improve the diagnostic accuracy for hepatic tumors on the liver surface, we investigated the usefulness of an indocyanine green-photodynamic eye (ICG-PDE) system by comparison with Sonazoid intraoperative ultrasonography (IOUS) in 117 patients. Hepatic segmentation by ICG-PDE was also evaluated. Methods ICG was administered preoperatively for functional testing and images of the tumor were observed during hepatectomy using a PDE camera. ICG was injected into portal veins to determine hepatic segmentation. Results Accurate diagnosis of liver tumors was achieved with ICG-PDE in 75% of patients, lower than with IOUS (94%). False-positive and false-negative diagnosis rates for ICG-PDE were 24% and 9%, respectively. New small HCCs were detected in 3 patients. The ICG fluorescent pattern in tumors was strong staining in 41%, weak staining in 13%, rim staining in 20% and no staining in 26%. Hepatocellular carcinoma predominantly showed strong staining (61%), while rim staining predominated in cholangiocellular carcinoma (60%) and liver metastasis (55%). Hepatic segmental staining was performed in 28 patients, proving successful in 89%. Conclusion ICG-PDE is a useful tool for detecting the precise tumor location at the liver surface, identifying new small tumors, and determining liver segmentation for liver resection.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
34
References
50
Citations
NaN
KQI