Covered Stent to Salvage Iatrogenic Vertebral Artery Injury with Uncontrolled Bleeding in the Operating Room Setting

2019 
Background Iatrogenic vertebral artery injury is an uncommon but well recognized complication during cervical spine surgery. Intraoperative surgical repair is extremely challenging, and options for endovascular repair are limited because of the lack of proper equipment in the operating room setting. Case Description A 53-year-old woman who presented with myelopathy underwent anterior cervical diskectomy and fusion of C3-7. A significant laceration injury of the left vertebral artery was encountered during surgery, which was salvaged by intraoperative endovascular repair with a covered stent under portable fluoroscopy guidance. The salvage and repair led to the rest of the surgery being finished as planned preoperatively without any consequences. Conclusions Vertebral artery injury is an uncommon but severe complication of cervical spine surgery. For uncontrolled bleeding, intraoperative endovascular repair with portable fluoroscopy is warranted and possible. A covered stent can seal the laceration and stop the bleeding completely which enables completion of the surgery.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    20