AB0990 Automated Ultrasound for the Detection of Synovitis in the Feet of Patients with Rheumatoid Arthritis (RA)
2014
Background The automated breast volume scanner (ABVS), which was developed to acquire series of consecutive B-mode pictures of the female breast, has been used successfully for the detection of synovitis in finger joints of RA patients. Objectives To evaluate whether ABVS can be used for the detection of synovitis in foot joints of RA patients. Methods 30 patients with RA were examined clinically and by manual high resolution ultrasound. ABVS was conducted using the ACUSON S2000™. The ABVS transducer was equipped with a linear array (5 – 14 MHz band width); the frequency was set at 11 MHz. Each automatic sweep of the scanner generated 15.4 x 16.8 cm x maximum 3 cm volume data sets. The system was set to perform an automatic scanning time of 65 s per scan with a slice thickness of 0.5 mm. Results 30 patients with RA were examined. 23 of them were female, the mean age was 63 years, the mean DAS28 was 4.55 with mean 8.7 tender and 7.3 swollen joints. The feet were not evaluable due to metatarsophalangeal (MTP) joint resection or gross deformity in 10 patients, resulting in 200 evaluable MTP joints. Swelling was detected by clinical examination in 13% of all MTPs. Manual ultrasound revealed swelling in 25%, the ABVS in 27% of the MTP joints. Conclusions ABVS is a simple and time sparing option for effective detection of small joint synovitis not only in the hands but also the feet of patients with RA. Disclosure of Interest None declared DOI 10.1136/annrheumdis-2014-eular.3742