Plymouth randomized trial of cardiotocogram only versus ST waveform plus cardiotocogram for intrapartum monitoring in 2400 cases

1993 
Objective: The physiology of changes in the ST waveform of the fetal electrocardiogram has been elucidated in extensive animal and human observational studies. A combination of heart rate and ST waveform analysis might improve the predictive value of intrapartum monitoring. Our purpose was to compare operative intervention and neonatal outcome in labors monitored by the conventional cardiotocogram with those monitored by ST waveform plus the cardiotocogram. Study Design: A prospective, randomized clinical trial was performed on 2434 high-risk labors in a district general hospital in Plymouth, England. Statistical analysis was performed by Student t test and χ 2 analysis. Results: There was a 46% reduction ( p p = 0.09, odds ratio 0.38 [0.13–1.07]) and fewer low 5-minute Apgar scores ( p = 0.12, odds ratio 0.62 [0.35–1.08]) in the ST waveform plus cardiotocogram arm. Conclusions: ST waveform analysis discriminates cardiotocogram changes in labor, and the protocol for interpretation is safe. Further randomized studies are warranted.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    28
    References
    210
    Citations
    NaN
    KQI
    []