Measurement of the transfer function for a spoke cavity of C-ADS Injector I
2017
The spoke cavities mounted in the China Accelerator Driven sub-critical System (C-ADS) have high quality factor(Q) and very small bandwidth, making them very sensitive to mechanical perturbations whether external or self-induced. The transfer function is used to characterize the response of the cavity eigen frequency to the perturbations. This paper describes a method to measure the transfer function of a spoke cavity. The measured Lorentz transfer function shows there are 206 Hz and 311 Hz mechanical eigenmodes excited by Lorentz force in the cavity of C-ADS, and the measured piezo fast tuner transfer function shows there are 12 mechanical eigenmodes from 0 to 500 Hz. According to these results, some effective measures have been taken to weaken the influence from helium pressure fluctuation, avoid mechanical resonances and improve the reliability of RF system.