Impact of aeration and deaeration of switchable vacuum insulations on the overall heat conductivity using different core materials and filling gases

2020 
Investigating switchable vacuum insulation panels might lead to a new type of insulation, which can be switched on to enable a low heat flow when a good insulation effect is desired and switched off when exchange with the environment is requested, during a cold summer night, for example. For this reason, different core materials for vacuum insulations as typical silica powder were investigated as well as silica agglomerates and silica gel. These materials were checked for the necessary time of aeration and evacuation and the corresponding change of heat conductivity along with the change of gas-pressure. Silica gel in combination with helium as filling gas showed best results corresponding to a high difference of the heat conductivities evacuated and aerated. Beside the solid backbone structure of the silica gel, this is caused by the high heat conductivity and small kinetic atomic diameter of the helium gas. Silica agglomerates decreased the aeration time as well as the deaeration time, but the improvement was neglected because of a lower change of heat conductivity during pressure drop or rise. Nevertheless, a good switchable vacuum insulation can be produced using silica gel and helium, for example.