Prosthesis-patient mismatch causes a significantly increased risk of operative mortality in aortic valve replacement.

2014 
Background: Small aortic prosthesis can lead to prosthesis-patient mismatch (PPM). Implanting such small prosthesis remains a controversial issue. This study was done to investigate whether or not PPM causes an increased operative mortality in aortic valve replacement (AVR). Methods: Two-hundred-two consecutive patients undergoing primary AVR in a tertiary hospital were included. The sample was grouped according to the aortic valve prosthesis size: ?21 mm (small) and >21 mm (standard). The effect of variables on outcomes was determined by univariate and multivariable regression analyses. Results: PPM was found significantly more among patients with AVR ? 21mm ( P P Conclusion: PPM and female gender are significant predictors of mortality. Care should be taken to prevent PPM by implanting larger prosthesis especially in females.