Comparison of Coal- and Oil-Fired Boilers through the Investigation of Filterable and Condensable PM2.5 Sample Analysis

2018 
This study investigated the characteristics of both filterable fine particulate matter (FPM) and condensable particulate matter (CPM) emitted from coal-fired boilers (CFBs) and oil-fired boilers (OFBs) via field sampling. FPM and CPM samples were collected using USEPA Method 201A and Method 202, respectively. Mass concentrations and chemical compositions (including water-soluble ions, metal elements and carbon contents) of collected PM2.5 samples were analyzed. The results show that PM2.5 (FPM + CPM) emission concentrations for CFBs and OFBs are 20.2 ± 10.4 and 157 ± 82.7 mg/Nm3, respectively. In terms of the emission factor, emission of FPM from OFBs is 307.4 ± 50 g/kL of oil and from CFBs is 57.1 ± 13.8 g/t of coal. Significantly higher concentrations are emitted from OFBs than from CFBs due to the reason that better control devices are installed in most CFBs. The average CPM fraction constitutes 58.7 and 54.8% of PM2.5 for CFBs and OFBs, respectively, showing that CPM from the boilers contributes a sig...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    39
    References
    22
    Citations
    NaN
    KQI
    []