Study of fracture toughness and bend test morphologies of HVOF sprayed Cr3C2-25% NiCr coating after heat treatment

2018 
Majority of the industrial components are subjected to high temperature exposure, where crack propagation occurs due to shear failure. The paper involves the study of the fracture toughness of heat treated Cr3C2-NiCr coating at three different service temperatures (750°C, 850°C, and 950°C for 1-hour aging) using indentation techniques to measure the crack resistance of the coating. At 750°C and 850°C, the coating cracked at the bend area, but not spalled. At 950°C, the coating spalled and delaminated from the substrate indicating poor adhesion after prolonged exposure. The influence of heat treatment on the fracture toughness and adhesion properties of the Cr3C2-25%NiCr coating were also investigated. The high temperature exposure at 950°C, resulted in a shear failure of the coating due to the presence of splat contraction. The increase in temperature increases the fracture toughness KIC of the coating, with the decrease in hardness. It was observed that the oxidation levels enhanced on the top layer of the coating, which acted like a core region for crack initiation at 950°C resulting in shear failure during bend test.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    14
    References
    1
    Citations
    NaN