Soil Water Sensor Performance and Corrections with Multiple Installation Orientations and Depths under Three Agricultural Irrigation Treatments

2019 
Performance evaluations and corrections of soil water sensors have not been studied using different installation orientations under various irrigation treatments in the Texas High Plains. This study evaluated the performance of four sensors using factory calibration and derived field corrections as compared to calibrated neutron moisture meters (NMMs). Sensor performance was assessed using horizontal insertion, laid horizontal placement, and vertical insertion at 15.2, 45.7, and 76.2 cm depths in a clay loam soil with three irrigation treatments. Results indicated the factory-calibrated Acclima 315 L performed satisfactorily using horizontal insertion as compared to NMM measurements at 45.7 and 76.2 cm depths with a ±2% mean difference (MD) and 60 mm) in the 0.9 m soil profile using the Watermark 200SS. In summary, field corrections are required for Decagon GS1, Campbell Scientific 655, and Watermark 200SS sensors.