Modeling of PM Synchronous Machines Under Inter-turn Fault

2011 
This paper presents a theoretical approach as far as faulty Permanent Magnet Synchronous Machines (PMSM) are concerned. The knowledge of PMSM's behavior under inter-turn fault is very useful in order to check drive performances under fault conditions. Control, stability and fault detection often require faulty models. The aim of this paper is to develop a dynamical model of a PMSM under fault conditions without using circuit models coupled with finite element analysis (FEA). The method exposed in this paper only needs some preliminary FE computations that can be used in order to take into account of different winding distributions.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    5
    References
    1
    Citations
    NaN
    KQI
    []