The effect of paracorporeal pulsatile biventricular assist devices on allosensitization in adults: A comparison with left ventricular assist devices.

2021 
Abstract Ventricular assist devices (VADs) have been associated with the development of anti-HLA antibodies (‘allosensitization’), but data on devices providing biventricular support in adults are limited. We sought to characterize differences in HLA antibody formation in adult patients receiving left- (LVAD) versus biventricular- (BiVAD) assist devices as bridge to transplantation (BTT) by retrospectively reviewing the records of adult patients who have undergone VAD implantation at our institution. We assessed 82 patients supported with a pulsatile-flow paracorporeal BiVAD and compared them with 40 patients receiving LVAD till 2018. Forty-eight (58.5%) of the BiVAD and 23 (57.5%) of the LVAD patients were eventually transplanted (p = 0.91) with an average time to transplantation 559 and 598 days, respectively (p = 0.73). Evidence of sensitization pre-VAD was found in 11.0% of the BiVAD patients and 15.0% of the LVAD ones (p = 0.53); these percentages rose to 43.9% (p