미세기포 세척장비를 이용한 도로시설물 염화칼슘의 제거

2019 
This study was conducted to evaluate the optimal operating condition of ultra-fine bubble washing machine for removing calcium chloride from road concrete structure. The diameter of the ultra-fine bubble was measured to 196.6 ± 100.6 nm and the ultra-fine bubble concentration was measured to 1.36 × 108 cell/ml. As a result of the performance on the spray device of the washing machine, it was confirmed that the washing efficiency of 93% and 91% appeared at 100cm and 150cm of injection distance at 100bar injection pressure. By increasing the ultra-fine bubble generation cycles from 2 to 6, the chloride removal rate increased from 1% to 7%. As the ultra-fine bubble generation air flow was lowered from 4 ml/min to 0.5 ml/min, it was confirmed that the washing efficiency increased up to 30%. The washing efficiency of ultra-fine bubble water was 25% higher than normal water.