2013 
OBJECTIVES: We evaluated our single-centre clinical experience with the HeartMate II (HM II) left ventricular assist device (LVAD) as a bridge to transplantation (BTT) in end-stage heart failure (HF) patients. METHODS: Survival rates, echocardiographic parameters, laboratory values and adverse events of 85 consecutive patients supported with a HM II were evaluated. RESULTS: Overall, mean age was 45±13 years, 62 (73%) were male and non-ischaemic dilatated cardiomyopathy was present in 60 (71%) patients. The median duration of mechanical support was 387 days (IQR 150–600), with a range of 1–1835 days. The 6-month, 1-, 2-, 3- and 4-year survival rates during HM II LVAD support were 85, 81, 76, 76 and 68%, respectively. Echocardiographic parameters demonstrated effective left ventricular unloading, while laboratory results reflected adequate organ perfusion. However, HM II support was associated with adverse events, such as infections in 42 patients (49%; 0.67 events/patient-year), cardiac arrhythmia in 44 (52%; 0.86 events/patient-year), bleeding complications in 32 (38%; 0.43 events/patient-year) and neurological dysfunction in 17 (20%; 0.19 events/patient-year). CONCLUSIONS: In view of the increasing shortage of donor hearts, HM II LVAD support may be considered a life-saving treatment in endstage HF patients, with good survival. However, it is still associated with some serious adverse events, of which neurological complications are the most critical.