Effect of particle stratification on debris-bed dryout. [LMFBR]

1982 
Significant work has been performed on debris-bed dryout on beds of either uniformly sized particles or particles of a wide size range which are well mixed. This work has provided an understanding of the mechanisms of dryout and an empirical basis for containment analysis. However, the debris bed resulting from a HCDA would not consist of uniformly sized particles and for certain scenarios the bed could be stratified rather than well mixed. Tests have been conducted on the effect of particle size distribution on dryout and concluded that not only is the mean particle size an important parameter but also the standard deviation of the distribution and change in porosity. The D6 in-pile test at Sandia with a 114-mm deep stratified bed resulted in a reduced dryout heat flux compared to a uniformly mixed bed. Because of the many questions concerning the dryout behavior of stratified beds of wide size distribution out-of-pile experiments in which metal particles in water pools are inductively heated were initiated at Argonne.