Abstract We describe a method to monitor ageing effects in the multiwire proportional chambers (MWPCs) of the barrel ring imaging Cherenkov (BRICH) detector of DELPHI. It is based on a measurement of plateau-curve characteristics and the shift of these as a function of the total collected charge. Results indicate that, as yet, no ageing effects are present.