Semi-Insulating Inp Obtained by Co-Implantation of Mg and Ti
1992
Implantation of magnesium acceptor in semi-insulating InP:Fe leads to a p-type layer which is further implanted with the low diffusitivity titanium deep donor, the sample recovering the semi-insulating behavior.