Measurement of Differential Renal Function by Scintigraphy in Hydronephrotic Kidneys: Importance of Conjugate Views for Accurate Evaluation

2016 
Purpose: Traditionally a single posterior view is used to measure differential renal function during nuclear renal scintigraphy. Nevertheless, experimental data show important variation in this measurement in the setting of significant hydronephrosis. To date, the impact of degree of hydronephrosis on the accuracy of differential renal function determination has not been addressed. We evaluated the discrepancy between function measured by anterior and posterior views, and the relationship to varying degrees of hydronephrosis.Materials and Methods: We retrospectively reviewed consecutive mercaptoacetyltriglycine renal scans from 2009 to 2011. Ultrasounds were reviewed and degree of hydronephrosis was recorded using anteroposterior pelvic diameter. Absolute percent difference in differential renal function between each view (anterior minus posterior) was calculated and correlated to anteroposterior pelvic diameter. Patients were stratified into 4 groups according to anteroposterior pelvic diameter, ie less ...