Electromagnetic coupling analysis of Radial-Radial flux Compound-Structure Permanent-Magnet Synchronous Machine used for HEVs

2014 
The electromagnetic coupling problem, which is created by stator machine (SM) and double-rotor machine (DRM) of Compound-Structure Permanent-Magnet Synchronous Machine (CS-PMSM), has a bad influence on CS-PMSM performance. In order to solve this problem, a 100kW Radial-Radial flux CS-PMSM used for HEVs is designed, and the electromagnetic coupling is researched when CS-PMSM works in stable conditions. As a conclusion, the electromagnetic coupling between inner and outer windings can be ignored when CS-PMSM works in stable condition. The conclusion is helpful to the aspect of motor design and mathematical model simplification.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    9
    References
    0
    Citations
    NaN
    KQI
    []