Influence of magnetic water on early-age shrinkage cracking of concrete

2017 
Abstract This research investigates the shrinkage cracking of concrete, which were mixed with magnetic water. Magnetic water was obtained by the independent designed magnetizing equipment. Ring-test method and flat-test method were used to test early-age shrinkage cracking of concrete. Results show that the strain rate factor ( α ) and the total cracking area of unit area ( c ) of concrete were decreased when used magnetic water, which means the early-age shrinkage cracking resistance of concrete mixed with magnetic water is improved than those mixed with tap water. The best increase in early-age shrinkage cracking resistance of concrete is achieved when the magnetic strength is 260 mT and the length of magnetic field is 280 mm. Additionally, the compressive and split strength of concrete mixed with magnetic water increased greatly. It is also found that the length of magnetic field have direct effect on the growth of concrete strength.