Magnetic resonance electrical impedance tomography at 3 tesla field strength

2004 
Magnetic resonance electrical impedance tomography (MREIT) is a recently developed imaging technique that combines MRI and electrical impedance tomography (EIT). In MREIT, cross-sectional electrical conductivity images are reconstructed from the internal magnetic field density data produced inside an electrically conducting object when an electrical current is injected into the object. In this work we present the results of electrical conductivity imaging experiments, and performance evaluations of MREIT in terms of noise characteristics and spatial resolution. The MREIT experiment was performed with a 3.0 Tesla MRI system on a phantom with an inhomogeneous conductivity distribution. We reconstructed the conductivity images in a 128 × 128 matrix format by applying the harmonic Bz algorithm to the z-component of the internal magnetic field density data. Since the harmonic Bz algorithm uses only a single component of the internal magnetic field data, it was not necessary to rotate the object in the MRI scan. The root mean squared (RMS) errors of the reconstructed images were between 11% and 35% when the injection current was 24 mA. Magn Reson Med 51:1292–1296, 2004. © 2004 Wiley-Liss, Inc.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    19
    References
    56
    Citations
    NaN
    KQI
    []