Percutaneous trans‐abdominal external looped needle with two holes in the trocar sheath for port‐site closures in difficult obese cases

2016 
Introduction Port closure is essential after successful laparoscopic surgery to prevent incisional hernia. However, good fascial closure still represents a problem, especially in obese patients and when the port wound is oblique. We report a novel technique for port-site closures in such cases. Methods This study involved 67 obese patients who underwent laparoscopic surgery. We used a novel technique for port-site closure that employed a looped needle passed through two holes in the port sheath. Results The method was used in 67 patients (45 laparoscopic cholecystectomies, 22 laparoscopic hernia repairs), with a mean BMI of 35.7 kg/m2. No intraoperative incidents or port-site hernias were reported during follow-up (mean, 22 months). Conclusion Our procedure is safe, easy, and effective for fascial port site closures, especially in cases of difficult obese patients and oblique port wounds.