A click-chemistry based strategy for labeling an anti-phosphatidylserine (PS) antibody with copper-64 via a cross-bridged tetraazamacrocyclic chelator scaffold

2014 
The κ-opioid receptors (KORs) are implicated in several neuropsychiatric diseases and addictive disorders. PET with radioligands provides a means to image the KOR in vivo and investigate its function in health and disease. The purpose of this study was to develop the selective KOR antagonist 11C-LY2459989 as a PET radioligand and characterize its imaging performance in nonhuman primates. Methods: LY2459989 was synthesized and assayed for in vitro binding to opioid receptors. Ex vivo studies in rodents were conducted to assess its potential as a tracer candidate. 11 CLY2459989 was synthesized by reaction of its iodophenyl precursor with 11 C-cyanide, followed by partial hydrolysis of the resulting 11 C-cyanophenyl intermediate. Imaging experiments with 11 CLY2459989 were performed in rhesus monkeys with arterial input function measurement. Imaging data were analyzed with kinetic models to derive in vivo binding parameters. Results: LY2459989 is a full antagonist with high binding affinity and selectivity for KOR (0.18, 7.68, and 91.3 nM, respectively, for κ, μ, and δ receptors). Ex vivo studies in rats indicated LY2459989 as an appropriate tracer candidate with high specific binding signals and confirmed its KOR binding selectivity in vivo. 11 C-LY2459989 was synthesized in high radiochemical purity and good specific activity. In rhesus monkeys, 11C-LY2459989 displayed a fast rate of peripheral metabolism. Similarly, 11C-LY2459989 displayed fast uptake kinetics in the brain and an uptake pattern consistent with the distribution of KOR in primates. Pretreatment with naloxone (1 mg/kg, intravenously) resulted in a uniform distribution of radioactivity in the brain. Further, specific binding of 11C-LY2459989 was dosedependently reduced by the selective KOR antagonist LY2456302 and the unlabeled LY2459989. Regional binding potential values derived from the multilinear analysis-1 (MA1) method, as a measure of in vivo specific binding signal, were 2.18, 1.39, 1.08, 1.04, 1.03, 0.59, 0.51, and 0.50, respectively, for the globus pallidus, cingulate cortex, insula, caudate, putamen, frontal cortex, temporal cortex, and thalamus. Conclusion: The novel PET radioligand 11 C-LY2459989 displayed favorable pharmacokinetic properties,
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    41
    References
    23
    Citations
    NaN
    KQI
    []