Development of MisMatch Transmission Line (MMTL) system for ICH&CD test rig

2015 
India is responsible for delivery of 8+1(prototype) RF sources to ITER Organization. Each RF source will provide 2.5MW of RF power at 2 VSWR in the frequency range of 35 to 65MHz with other stringent specifications. To test the sources at full performance, India is developing unique 3MW test facility with variable load condition (up to VSWR 3.0 at any phase angle in between 0°-360°), consisting of high power 50 Ohm dummy load, phase shifter and stub. The combined assembly of phase shifter and stub is called MisMatch Transmission Line (MMTL) system. Detailed RF and thermal simulation of the MMTL system has been done as a part of developmental activity. Simulations predict maximum RF voltage and current in the MMTL system are 18kV and 400A, respectively. Thermal simulation shows that system can be operated at 1.7MW/CW/3VSWR without active cooling. A detailed design and initial test results of MMTL system considering RF & mechanical aspect for testing ITER ICRF sources is described in this paper.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    0
    Citations
    NaN
    KQI
    []