Perte d'information diagnostique par utilisation de méthodes non recommandées pour le dosage de la testostérone chez la femme Testosterone assays using non recommended methods lead to misdiagnosis in women

2017 
French and US endocrine societies recommend using GC-MS or RIA after purification (extraction + chromatography) to assess blood levels of testosterone in women. However, most of laboratories use automatized methods that have to be reserved to measure testosterone levels in men. The aim of this study was to show the consequences of analytical discrepancies of some immunological methods on the diagnostics values of testosterone levels assayed in women. Compared to GC-MS the correlations of the assayed levels varied (Spearman's rank correlation coefficients: 0.935; 0.793; 0.841; 0.852 respectively for RIA Immunotech™ with extraction and chromatographic purification; Testosterone Access-DxI800 ® ; Testosterone Immulite 2000 ® ; Testosterone II Cobas E601 ® ). The testosterone levels allowed an accurate conclusion in 95.2 %; 75.8 %; 77.4 %; 89.8 % of patients, respectively. The agreement with GC-MS results was very good for RIA method (κ=0,840), moderate for DxI800 ® method (κ=0,414), moderate for Immulite ® method