Augmented efficacy of external CPR by intermittent occlusion of the ascending aorta.

1993 
BACKGROUNDAfter prolonged cardiac arrest, conventional methods of closed-chest cardiac compression are ineffective. This is primarily because of failure to generate minimal threshold levels of coronary perfusion pressure for cardiac resuscitation. This report introduces a new option for cardiac resuscitation by use of a combination of intermittent ascending aortic balloon occlusion, aortic infusion, and precordial compression to increase the pressure gradient for coronary perfusion.METHODS AND RESULTSTwenty anesthetized, mechanically ventilated, normovolemic domestic pigs were investigated. A 10F balloon catheter was advanced from the left femoral artery into the ascending aorta. Ventricular fibrillation was induced with an AC current delivered through an electrode catheter advanced into the right ventricle. Precordial compression was initiated after 7 minutes of untreated ventricular fibrillation. The animals were randomized to one of four groups: (1) balloon occlusion with proximal infusion of oxygenate...