Study on Maximum Flow Rates and Sizing Method of Overflow Pipes in Water Tanks

2006 
When examining the standard of the air-gap in open tanks with overflow pipes, it is necessary to determine the height of the highest water level and maximum capacity of overflow pipe in tanks. However, it is not cleared not only to determine the height and the capacity, but also to decide the size of overflow pipe. Therefore, the experimental study was carried out for the purpose to obtain them. In this paper, it was reported the experiment result concerning the FRP water tank with overflow pipe of inside diameters 50 mm and 100 mm. As a result, empirical formulae of the height by incoming flow rates and inside diameters, and the maximum flow rate of overflow pipes are shown. Moreover, methods to decide the size of overflow pipes are proposed.