Union Rate and Rate of Hardware Removal Following Plate Fixation of Metatarsal Shaft and Neck Fractures

2018 
Background:There have been very few studies related to the treatment of first, second, third, and fourth (MT) metatarsal shaft and neck fractures. In order to reduce metatarsal fracture malunion, many surgeons have turned from K-wire to plate fixation of these fractures. This study reports the healing rates, final fracture angulation, and need for hardware removal of operatively treated first to fourth MT shaft and neck fractures with plate fixation.Methods:A retrospective review was performed on all metatarsal fractures at our institution between 2008 and 2014 to identify all first to fourth MT shaft and neck fractures. Medical records and radiographs were reviewed for evidence of union, sagittal, and coronal fracture angulation (degrees), time to full weight bearing, plate size, fracture location (neck vs shaft), and number of screws on each side of the fracture. Multiple linear regression analysis was used to make calculations of statistical significance.Results:Forty-five patients with a total of 75 f...