Triggering techniques for a compact Marx generator

1994 
Optically controlled, sequential breakdown of the spark‐gap switches is a simple method for triggering compact Marx generators. Techniques for reliably initiating breakdown of the first switch are discussed. A 300‐kV Marx generator for flash x‐ray applications is described.