An experimental model for the prevention of postanastomotic tracheal stenosis.
1997
Abstract Objective: The aim of the current study is to determine the efficiency of an external prosthesis made of expanded polytetrafluoroethylene reinforced with a continuous silicone spiral to prevent postanastomotic stenosis after surgical correction of extensive tracheal defects in rabbits. Methods: Forty-five rabbits were used, divided into three groups of 15 animals each. Group A was the control group. Group B animals underwent resection of six-ring segments of the cervical trachea and primary anastomosis. The procedure used in group C was similar to that used in group B, but the tracheal anastomosis was supported by an external expanded polytetrafluoroethylene prosthesis. Results: Direct anastomosis after resection of six tracheal rings caused anastomotic stenosis in 100% of the animals. We did not observe tracheal stenosis in any rabbit when we applied an expanded polytetrafluoroethylene tube as an external stent for the tracheotracheal suture. Conclusion: We conclude that an external stent can be used to prevent tracheal stenosis resulting from the resection of six cervical tracheal rings in rabbits(J Thorac Cardiovasc Surg 1997;114:76-83)
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
31
References
13
Citations
NaN
KQI