Effects of Different Rotary Files Combined with Different Irrigation Needles on Apically Extruded Debris
2015
The aim of this study was to compare the apically extruded debris associated with ProTaper Next and OneShape Apical files using two different irrigation needles, open-ended and closed-ended (Max-I-Probe). Forty-eight mandibular premolars were assigned to four groups (n=12) as follows: Group PTN-SN: Root canal was prepared with ProTaper Next (PTN) and irrigated with open-ended standard needle; Group PTN-MP: Root canal was prepared with PTN and irrigated with Max-I-Probe; Group OSA-SN: Root canal was prepared with OneShape Apical (OSA) and irrigated with open-ended needle; Group OSA-MP: Root canal was prepared with OSA and irrigated with Max-I-Probe. Debris extruded during instrumentation was collected into pre-weighed Eppendorf tubes. After storage in an incubator at 70 °C for 5 days, the Eppendorf tubes were weighed to obtain the final weight with extruded debris. The difference between pre-and post-debris weights was calculated and statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests (p 0.05). OneShape Apical and ProTaper Next resulted in extrusion of debris beyond the apical foramen, regardless of needle tip.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
26
References
2
Citations
NaN
KQI