Respirator fit factor performance while sweating.

1999 
The extent to which sweat accumulation inside respirators affects respirator fit has not been quantified. This study represents an attempt to measure facial sweating and to quantify its effects on fit factors of negative pressure, full-facepiece respirators. Respirator fit factor (FF) data were obtained while 14 subjects completed 30 minutes of treadmill walking at an intensity of 75% of age-predicted maximal heart rate in an aerosol test chamber under ambient environmental conditions. Subject facial and whole body sweat production were also measured. Statistical analysis of the treadmill FF results showed that respirator fit was significantly (p<0.05) degraded after 14 minutes of exercise. Sweat accumulation inside the respirator facepiece averaged 30.9±15.5 g. However, no significant correlation of subject facial sweat production with overall FF values measured during exercise was found. The results of this study indicate that respirator FFs degrade significantly over time under moderate exercise and en...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    10
    References
    4
    Citations
    NaN