Ablation of Stable VTs Versus Substrate Ablation in Ischemic Cardiomyopathy: The VISTA Randomized Multicenter Trial.

2015 
Abstract Background Catheter ablation reduces ventricular tachycardia (VT) recurrence and implantable cardioverter defibrillator shocks in patients with VT and ischemic cardiomyopathy. The most effective catheter ablation technique is unknown. Objectives This study determined rates of VT recurrence in patients undergoing ablation limited to clinical VT along with mappable VTs (“clinical ablation”) versus substrate-based ablation. Methods Subjects with ischemic cardiomyopathy and hemodynamically tolerated VT were randomized to clinical ablation (n = 60) versus substrate-based ablation that targeted all “abnormal” electrograms in the scar (n = 58). Primary endpoint was recurrence of VT. Secondary endpoints included periprocedural complications, 12-month mortality, and rehospitalizations. Results At 12-month follow-up, 9 (15.5%) and 29 (48.3%) patients had VT recurrence in substrate-based and clinical VT ablation groups, respectively (log-rank p  Conclusions An extensive substrate-based ablation approach is superior to ablation targeting only clinical and stable VTs in patients with ischemic cardiomyopathy presenting with tolerated VT. (Ablation of Clinical Ventricular Tachycardia Versus Addition of Substrate Ablation on the Long Term Success Rate of VT Ablation (VISTA); NCT01045668 )
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    209
    Citations
    NaN
    KQI
    []