Historically, immune-mediated degradation and subsequent aneurysm formation have limited the usefulness of cryopreserved arterial allografts. This study tested the hypothesis that modern cryopreserved arterial allografts are protected from immune-mediated dilation. Abdominal aortas were harvested from anesthetized rats (Lewis and Brown-Norway) for immediate implantation or cryopreservation. Subsequently, Lewis rats underwent infrarenal aortic replacement with either an acutely harvested or a cryopreserved graft. There were four experimental groups: (1) acutely harvested isografts (Iso; n = 6), (2) cryopreserved isografts (C-Iso; n = 6), (3) cryopreserved allografts (C-Allo; n = 6), and (4) acutely harvested allografts (Allo; n = 6). All grafts were explanted at 8 weeks. A video camera and edge detection software were used to measure systolic and diastolic in vivo graft diameter ( d ). Measurement of arterial blood pressure (p) allowed calculation of compliance (δ d /δp). Tall-cuff plethysmography was used to assess graft patency at 1 week. Graft diameter and blood pressure measurements were repeated at harvest. All harvested grafts were examined histologically. Our results showed that cryopreservation prevented immune-mediated dilation in arterial allografts in our 8-week rat implant model. Furthermore, the compliance of the cryopreserved grafts and was similar to that of controls. Further investigation is needed to delineate the exact mechanism of these potential cliniclly significant findings.