Effect of radon measurement methods on dose estimation

2011 
Different radon measurement methods were applied in the old and new buildings of the Turkish bath of Eger, Hungary, inorder to elaborate a radon measurement protocol. Besides, measurements were also made concerning the radon and thoronshort-lived decay products, gamma dose from external sources and water radon. The most accurate results for dose estimationwere provided by the application of personal radon meters. Estimated annual effective doses from radon and its short-liveddecay products in the old and new buildings, using 0.2 and 0.1 measured equilibrium factors, were 0.83 and 0.17 mSv, respect-ively. The effective dose from thoron short-lived decay products was only 5 % of these values. The respective external gammaradiation effective doses were 0.19 and 0.12 mSv y
    • Correction