Neutron multiplicity counter development
1991
We have designed and built two multiplicity counters to test the usefulness of multiplicity counting for the safeguards assay of plutonium-bearing materials. The first prototype counter has been characterized and a variety of plutonium-bearing materials have been measured with it. Assays accurate to {approximately}0.7% have been obtained for both pure and impure plutonium oxide samples in reasonable measurement times. Assays accurate to {approximately}5% have been obtained for metal samples. A second multiplicity counter has been designed using experience gained from the first as well as Monte Carlo simulations. The second counter was designed to be more suitable for in-plant measurement of pyrochemical process materials. This paper presents the results of characterization studies of the two instruments. 10 refs., 9 figs., 2 tabs.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
0
References
9
Citations
NaN
KQI