Characterization of dry eye disease in a mouse model by optical coherence tomography and fluorescein staining
2019
A custom-built ultrahigh-resolution optical coherence tomography (UHR-OCT) system and fluorescein staining were employed for investigation of a scopolamine induced dry eye mouse model. Acquired data was used to evaluate common and complementary findings of the two modalities. Central corneal thickness as measured by UHR-OCT increased significantly over the study period of 24 hours, from 89.0 ± 3.57 µm to 92.2 ± 4.07 µm. Both techniques were able to show corneal lesions with a large range of severity. Localized fluorescein staining was detected in 5% and diffuse staining in 45% of cases where no epithelial damage was visible with OCT. However, OCT revealed stromal defects in 6% and endothelial defects in 18% of the cases, which could not be visualized via fluorescein staining. Thus, while fluorescein staining widely detected defects of the corneal surface in a mouse model of dry eye disease, OCT non-invasively revealed additional information about defect depth and involvement of particular layers.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
39
References
5
Citations
NaN
KQI