Development of a sensitive and stable GC-MS/MS method for simultaneous determination of four N-nitrosamine genotoxic impurities in sartan substances

2021 
Recently, N-nitrosamines have been unexpectedly found in generic sartan products. Herein, we developed a sensitive and stable GC-MS/MS method with multiple reactions monitoring mode for the simultaneous determination of four N-nitrosamines in sartan substances, namely, N-nitrosodimethylamine, N-nitrosodiethylamine, N-nitrosodibutylamine, and N-nitrosodiisopropylamine. The conditions of gas chromatography and mass spectrometry were optimized. The method was validated according to the International Council for Harmonization guidelines in terms of sensitivity, linearity, accuracy, precision, specificity, and stability. The limits of detection of N-nitrosamines in sartan substances ranged from 0.002 to 0.150 ppm, and the corresponding limits of quantification were in the range of 0.008-0.500 ppm, which met the sensitivity requirements for the limits set by the Food and Drug Administration of the United States. The internal standard curve of four N-nitrosamines showed good linearity of regression coefficients over 0.99. The recoveries of N-nitrosamines in selected sartan drugs ranged from 87.68 to 123.76%. The intraday and interday relative standard deviation values were less than 9.15%. Therefore, this proposed method exhibited good sensitivity and precision, high accuracy, and fast analysis speed, which provide a reliable method for quality control of N-nitrosamines in sartan products.