COMPARISON OF PULMONARY NODULE DETECTION, READING TIMES AND PATIENT DOSES OF ULTRA-LOW DOSE CT, STANDARD DOSE CT AND DIGITAL RADIOGRAPHY.

2021 
The purpose of the present work was to evaluate performance in pulmonary nodule detection, reading times and patient doses for ultra-low dose computed tomography (ULD-CT), standard dose chest CT (SD-CT), and digital radiography (DR). Pulmonary nodules were simulated in an anthropomorphic lung phantom. Thirty cases, 18 with lesions (45 total lesions of 3-12 mm) and 12 without lesions were acquired for each imaging modality. Three radiologists interpreted the cases in a free-response study. Performance was assessed using the JAFROC figure-of-merit (FOM). Performance was not significantly different between ULD-CT and SD-CT (FOMs: 0.787 vs 0.814; ΔFOM: 0.03), but both CT techniques were superior to DR (FOM: 0.541; ΔFOM: 0.31 and 0.28). Overall, the CT modalities took longer time to interpret than DR. ULD chest CT may serve as an alternative to both SD-CT and conventional radiography, considerably reducing dose in the first case and improving diagnostic accuracy in the second.