COMPARATIVE ANALYSIS OF DIRECT FLUORESCENCE, ZENON LABELING, AND QUANTUM DOT NANOCRYSTAL TECHNOLOGY IN IMMUNOFLUORESCENCE STAINING

2010 
A comparative analysis was performed to determine the sensitivity and efficiency of three fluorescent labeling techniques, including direct fluorescent-antibody staining (FA), Zenon labeling, and quantum dot (QD) nanocrystal technology. Two varicella-zoster virus immunoglobin (Ig) G forms, mAb 4F9 and mAb g62, were selected for these studies. The results indicated that: (1) All three methods demonstrated similar brightness and photostability; (2) the time required to conjugate the antibody varied, with Zenon labeling being the quickest; and (3) the stability of each conjugated complex was different, with FITC/rhodamine-conjugated antibody being the most stable.